Eletricians can you tell me the correct depth to lay armoured cable to a shed please?

I am taking power to an new build shed I just reqire the depth to lay the armoured cable. Please note I was a semi skilled electrician and connection will be done by an niec approved engineer Regards SJ

over 500mm measured from the TOP of the cable.

Share and Enjoy:
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
  • services sprite Eletricians can you tell me the correct depth to lay armoured cable to a shed please?
Tags:

10 Responses to “Eletricians can you tell me the correct depth to lay armoured cable to a shed please?”

  1. rgirg says:

    codes differ from city to city and state to state. check your local codes. we don’t even know where you are
    References :

  2. Harry o says:

    if its armoured 18 inches would suffice
    References :

  3. rapid says:

    If laid direct in the ground and a warning tape laid above 450mm or 18" is OK
    References :

  4. anthony789795 says:

    regs to AS3000-AS3008 state 500mm with warning tape.
    References :

  5. WTF says:

    Use pvc. Then you can run phone,cable and power.
    References :

  6. HIFi333 says:

    depending on where you live. the frost level. is the depth that water will freeze in the winter time. I live in indiana. the depth would be about 2.5- 3 feet. I have a suggestion. call that phone number that tells you "call before you dig" and ask them. they only put the cable tv about 6" under. you are allowed to call the "county building inspector" on the phone and the will tell you the answer for your county. if it were me. I would make it about 6" deep. because. It doesn’t matter if electric cable gets frozen or not.
    so. look in the phone book . for county
    "building inspector" and ask him/her.
    References :

  7. yogi972 says:

    over 500mm measured from the TOP of the cable.
    References :
    guess what!?

    im a sparky ;-)

  8. Hugo S says:

    In the UK good practice is 18 inches.

    I particularly like the idea of running it in a length of 2" waste pipe, so you can run other services through at a later date. If you do this please make sure you clearly identify it as electrical though, in case someone digs it up later.

    Whatever you do, do not lay it in yellow or blue MDPE pipe! Yellow is for mains gas and blue is for water. We don’t want the gas or water supply companies cutting through the pipe, then getting electrocuted.
    References :

  9. Bubblestwo says:

    About 1ft should suffice but to be sure then you can consult
    the IEE onsite guide (possible available online if you google it)
    References :